Pressure Reducing Valves
Showing 13–24 of 49 results
Filter-
REXROTH Pressure reducing valves, sandwich module, direct operated (ZDR10 DP 1-5X/210 YM)
₹196.80Models ZDR are 3-way direct operated pressure reducing -relieving valves. They maintain a “reduced” pressure in a branch circuit and permit “relieving” pressure spike occurrences in the reduced branch circuit. Options for pressure ranges and operator adjustment options are within the scope of the modular reducing valve portfolio.
-
REXROTH Pressure reducing valves, sandwich module, direct operated (ZDR10 DP 2-5X/ 25 YM)
₹196.80Models ZDR are 3-way direct operated pressure reducing -relieving valves. They maintain a “reduced” pressure in a branch circuit and permit “relieving” pressure spike occurrences in the reduced branch circuit. Options for pressure ranges and operator adjustment options are within the scope of the modular reducing valve portfolio.
-
REXROTH Pressure reducing valves, sandwich module, direct operated (ZDR10 DP 2-5X/ 75 YM)
₹196.80Models ZDR are 3-way direct operated pressure reducing -relieving valves. They maintain a “reduced” pressure in a branch circuit and permit “relieving” pressure spike occurrences in the reduced branch circuit. Options for pressure ranges and operator adjustment options are within the scope of the modular reducing valve portfolio.
-
REXROTH Pressure reducing valves, sandwich module, direct operated (ZDR10 DP 2-5X/100 YM)
₹196.80Models ZDR are 3-way direct operated pressure reducing -relieving valves. They maintain a “reduced” pressure in a branch circuit and permit “relieving” pressure spike occurrences in the reduced branch circuit. Options for pressure ranges and operator adjustment options are within the scope of the modular reducing valve portfolio.
-
REXROTH Pressure reducing valves, sandwich module, direct operated (ZDR10 DP 2-5X/150 YM)
₹196.80Models ZDR are 3-way direct operated pressure reducing -relieving valves. They maintain a “reduced” pressure in a branch circuit and permit “relieving” pressure spike occurrences in the reduced branch circuit. Options for pressure ranges and operator adjustment options are within the scope of the modular reducing valve portfolio.
-
REXROTH Pressure reducing valves, sandwich module, direct operated (ZDR10 DP 2-5X/210 YM)
₹196.80Models ZDR are 3-way direct operated pressure reducing -relieving valves. They maintain a “reduced” pressure in a branch circuit and permit “relieving” pressure spike occurrences in the reduced branch circuit. Options for pressure ranges and operator adjustment options are within the scope of the modular reducing valve portfolio.
-
SUN HYDRAULICS Pilot-operated, pressure reducing main stage with integral T-8A control cavity (PBFB8WN)
₹412.80This valve is a normally open modulating element that incorporates an integral pilot control cavity. The pilot control cavity will accept any T-8A pressure control cartridge. The valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1. The pilot cartridge’s setting determines the difference in pressure between reduced pressure (port 1) and the drain (port 3).
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
-
SUN HYDRAULICS Pilot-operated, pressure reducing valve(PBBBLWN)
₹247.20Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- Minimum setting is 75 psi (5 bar) for all spring ranges.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges A, B, N, and Q are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Range W is tested with 5000 psi (350 bar) of inlet pressure.
-
SUN HYDRAULICS Pilot-operated, pressure reducing/relieving valve(PPBBLAN)
₹328.80Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
-
SUN HYDRAULICS Pilot-operated, pressure reducing/relieving valve(PPFBLAN)
₹475.20Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
-
YUKEN Modular Pressure Reducing Valve (MRA-01-C-30H16)
₹170.40Original price was: ₹170.40.₹110.40Current price is: ₹110.40.Pressure reducing valves are a type of pressure control valve. They maintain a largely constant outlet pressure even at a variable (higher) inlet pressure. Reducing Modular Valves MR*. Reducing modular valves MR* are used to set the pressure of a hydraulic circuit below that of the main circuit.
-
YUKEN Modular Pressure Reducing Valve (MRA-01-H-30H16)
₹170.40Original price was: ₹170.40.₹110.40Current price is: ₹110.40.Pressure reducing valves are a type of pressure control valve. They maintain a largely constant outlet pressure even at a variable (higher) inlet pressure. Reducing Modular Valves MR*. Reducing modular valves MR* are used to set the pressure of a hydraulic circuit below that of the main circuit.