Instant 5% OFF on Prepaid Orders

Logic Controls

Filter
  • SUN HYDRAULICS Normally closed, balanced poppet, logic element with integral T-8A control cavity – vent-to-open (DKFR8HN)

    626.40

    This is a normally closed, balanced poppet, switching element with an integral T-8A control cavity. With a 2-way valve in the closed position installed in the T-8A control cavity, the poppet remains closed. Opening the 2-way valve shifts the poppet to the open position, provided there is sufficient pressure at port 3.

    • Unique balanced construction provides predictable switching with 5000 psi (350 bar) at port 1 and port 2. Switching will only occur when both a minimum pilot pressure of 400 psi (30 bar) is present and pilot control valve is open.
    • These valves are hydraulically balanced between port 1 and port 2.
    • Port 1 and port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.
    • Any backpressure at the drain port is directly additive to the required pilot pressure for reliable operation.
    • Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
  • SUN HYDRAULICS Normally closed, balanced poppet, logic element with integral T-8A control cavity – vent-to-open (DKJR8HN)

    1,850.40

    This is a normally closed, balanced poppet, switching element with an integral T-8A control cavity. With a 2-way valve in the closed position installed in the T-8A control cavity, the poppet remains closed. Opening the 2-way valve shifts the poppet to the open position, provided there is sufficient pressure at port 3.

    • Unique balanced construction provides predictable switching with 5000 psi (350 bar) at port 1 and port 2. Switching will only occur when both a minimum pilot pressure of 400 psi (30 bar) is present and pilot control valve is open.
    • These valves are hydraulically balanced between port 1 and port 2.
    • Port 1 and port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.
    • Any backpressure at the drain port is directly additive to the required pilot pressure for reliable operation.
    • Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
    • Valve will reseat when the pilot pressure falls below 145 psi (10 bar).
  • SUN HYDRAULICS Pilot-to-close, spring-biased closed, unbalanced poppet logic element (LODCXDN)

    223.20

    These unbalanced, pilot-to-close logic valves are 2-way switching elements that are spring biased closed. Pressure at either work port 1 or 2 will oppose the spring and tend to open the valve while pressure at port 3 will tend to close it. The force generated at port 3, plus the spring force, must be greater than the sum of the forces acting at port 1 and port 2 for the valve to remain closed. NOTE: The pilot area (port 3) is 1.8 times the area at port 1 and 2.25 times the area at port 2.

    • These valves have positive seals between port 2 and the pilot area.
    • Because these valves are unbalanced, operation is pressure dependent. Opening and closing of the poppet are functions of the force balances on three areas: Port 1 = 100%, Port 2 = 80%, and the Pilot Area = 180%.
    • These valves are pressure responsive at all ports, therefore it is essential to consider all aspects of system operation through a complete cycle. Pressure changes at any one port may cause a valve to switch from a closed to an open position, or vice versa. All possible pressure changes in the complete circuit must be considered to assure a safe, functional system design.
    • All ports will accept 5000 psi (350 bar).
Shopping Cart

Product Filter

Product Enquiry

Scroll to Top