Instant 5% OFF on Prepaid Orders

SUN HYDRAULICS

Filter
  • SUN HYDRAULICS Fixed orifice pressure compensated flow control valve with reverse flow check (FCBBLAN)

    271.20

    Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1. The flow setting is specified by the user and is set at the factory.

    • Customer must specify a flow rating. Factory set flow ratings are within +/- 15% of the requested setting.
    • The tuneable control option provides +/- 20% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
    • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
    • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • SUN HYDRAULICS Fixed orifice, non-pressure compensated, flow control valve with reverse flow check (CNCCXCN)

    124.80

    This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is specified by the user and is set at the factory.

    • Customer must specify the orifice diameter.
    • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
    • These are essentially check valves with bypass orifices. The flow path matches Sun’s flow controls and can be used in any flow control manifolds. Valves with the opposite direction of flow can be found under check valves with bypass orifices.
    • Because these valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
  • SUN HYDRAULICS Fully adjustable needle valve – pilot capacity(NFABKXN)

    136.80

    Two-port, pilot-stage needle valves are fully adjustable devices used to regulate pilot flow in a main-stage valve or to meter in/out flow in low flow applications. These cartridges are designed for pilot flow applications and utilize Sun’s T-8A cavity so they can be used in conjunction with Sun’s pilot-operated, main-stage valves.

    • Utilizes the Sun T-8A 2-port cavity making it the ideal choice to use in conjunction with Sun’s main stage pilot or vent-to-operate cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-position, 2-way pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
    • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
    • Ports 1 and 2 may be pressured to 5000 psi (350 bar).
    • Needle adjusts from fully closed to fully open in three complete turns resulting in extremely fine resolution.
  • SUN HYDRAULICS Fully adjustable needle valve with reverse flow check (NCCBLAN)

    163.20

    Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1. They are not pressure compensated.

    • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
    • Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
    • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • SUN HYDRAULICS Fully adjustable needle valve with reverse flow check (NCFCLCN)

    439.20

    Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1. They are not pressure compensated.

    • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
    • Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
    • A balanced adjustment mechanism allows for easy adjustment even at high pressures.
    • The sharp-edged orifice design minimizes flow variations due to viscosity changes.